@ -79,7 +79,7 @@ Object Cross-Sectional Area & Uncertainty \\ \hline
\SI{20}{\milli\meter\squared} & \SI{10}{\percent} \\
\SI{120}{\milli\meter\squared} & \SI{4}{\percent} \\ \hline
\end{tabular}
\caption{Uncertainty of Cross-Sectional Area measurement for different sized objects}\label{table:cross_uncertainty}
\caption{Uncertainty of Cross-Sectional Area measurement for different sized objects.}\label{table:cross_uncertainty}
\end{table}
As shown in \autoref{table:cross_uncertainty}, measurements of the miniature cars---with cross-sectional areas of \SI{20}{\milli\meter\squared}---had a relatively high uncertainty of around \SI{10}{\percent}. The uncertainty was reduced to \SI{4}{\percent} when using a cardboard box of a larger size. This however, is to be expected according to the specified uncertainty of the LIDAR sensor at \SI{1}{\meter}.