@ -18,13 +18,6 @@ This transportation of bulk material flow introduces the need to accurately meas
|
|||||||
|
|
||||||
The conventional method of measuring bulk material flow in use in the industry today is the electronic belt scale---as shown in \autoref{fig:beltscale}. These scales use load cells to translate compression and tension into electrical signals. These signals representing weight may then be converted into measurements of volume.
|
The conventional method of measuring bulk material flow in use in the industry today is the electronic belt scale---as shown in \autoref{fig:beltscale}. These scales use load cells to translate compression and tension into electrical signals. These signals representing weight may then be converted into measurements of volume.
|
||||||
|
|
||||||
\begin{figure}[h]
|
|
||||||
\centering
|
|
||||||
\includegraphics[width=0.75\textwidth]{photographs/beltscale}
|
|
||||||
\caption{A conventional electronic belt scale.}
|
|
||||||
\label{fig:beltscale}
|
|
||||||
\end{figure}
|
|
||||||
|
|
||||||
These electronic belt scales are robust and proven in the field. However, there are also downsides with this approach.
|
These electronic belt scales are robust and proven in the field. However, there are also downsides with this approach.
|
||||||
|
|
||||||
\begin{enumerate}
|
\begin{enumerate}
|
||||||
@ -33,6 +26,13 @@ These electronic belt scales are robust and proven in the field. However, there
|
|||||||
\item Vibration from transport and loading introduces noise into the measurements \cite{tomobe2006}
|
\item Vibration from transport and loading introduces noise into the measurements \cite{tomobe2006}
|
||||||
\end{enumerate}
|
\end{enumerate}
|
||||||
|
|
||||||
|
\begin{figure}[h]
|
||||||
|
\centering
|
||||||
|
\includegraphics[width=0.75\textwidth]{photographs/beltscale}
|
||||||
|
\caption{A conventional electronic belt scale.}
|
||||||
|
\label{fig:beltscale}
|
||||||
|
\end{figure}
|
||||||
|
|
||||||
\section{Aims of this Work}\label{sec:aims}
|
\section{Aims of this Work}\label{sec:aims}
|
||||||
|
|
||||||
%\subsection{Research Question}
|
%\subsection{Research Question}
|
||||||
|
@ -39,11 +39,13 @@ After calibration, the current slice curve $g(x)$ can be used to obtain the Cros
|
|||||||
\subsubsection{Further Considerations}
|
\subsubsection{Further Considerations}
|
||||||
The accuracy of the computed cross-sectional area depends primarily on the accuracy of the depth data as well the frame rate of the sensor.
|
The accuracy of the computed cross-sectional area depends primarily on the accuracy of the depth data as well the frame rate of the sensor.
|
||||||
|
|
||||||
|
\begin{minipage}{\textwidth}
|
||||||
However, further operations may be implemented in order to increase accuracy, such as:
|
However, further operations may be implemented in order to increase accuracy, such as:
|
||||||
\begin{itemize}
|
\begin{itemize}
|
||||||
\item Computing the cross-sectional area from multiple slices of each frame and averaging these
|
\item Computing the cross-sectional area from multiple slices of each frame and averaging these
|
||||||
\item Computing the average cross-sectional area between frames, in order to create a smoother---and possibly more accurate---estimation of the volume flow
|
\item Computing the average cross-sectional area between frames, in order to create a smoother---and possibly more accurate---estimation of the volume flow
|
||||||
\end{itemize}
|
\end{itemize}
|
||||||
|
\end{minipage}
|
||||||
|
|
||||||
It is important to note though, that the implementation of further operations may exhaust the processing capabilities of the platform. Therefore, a crucial balance must be struck between performance and accuracy.
|
It is important to note though, that the implementation of further operations may exhaust the processing capabilities of the platform. Therefore, a crucial balance must be struck between performance and accuracy.
|
||||||
|
|
||||||
|
Before Width: | Height: | Size: 36 KiB After Width: | Height: | Size: 47 KiB |
Before Width: | Height: | Size: 56 KiB After Width: | Height: | Size: 75 KiB |
Before Width: | Height: | Size: 16 KiB After Width: | Height: | Size: 22 KiB |
Before Width: | Height: | Size: 26 KiB After Width: | Height: | Size: 35 KiB |